CXS-5MWB

5 MWh Stationary DC Block

A 5,015.9 kWh / 2,507.5 kW DC, liquid-cooled stationary battery DC block in a single 20-ft ISO container. Pairs with any utility-scale external PCS for grid services, microgrids, industrial backup and remote regions that are grid-isolated.

Energy

5,015.9 kWh

DC Power

2,507.5 kW

Parallel Units

Ambient

−40 / +50 °C

Engineering Brief

Safe and Reliable

Pairs with any utility-scale external PCS for peak shaving, frequency response, capacity firming and black-start service — no inverter inside the container.

Endure

Closed-loop liquid cooling, IP55 container / IP67 pack ingress, multi-stage suppression and a −40 / +50 °C envelope for continuous duty.

Secure

Optional hardware QRNG signs comms and firmware — closing the entropy gap that breaks classical control and monitoring PRNGs.

Mission Use Cases

Grid Services

Peak shaving, frequency response, capacity firming and black-start service via an external utility-scale PCS skid.

Industrial Backup

High-availability backup for data centres, ports and heavy industry — 14 days from pad pour to first dispatch.

Remote Regions

Sovereign 5 MWh-class storage for diesel displacement and renewable firming in microgrids.

Full Specifications

Energy and DC Power

Nominal energy
5,015.9 kWh (5.0 MWh)
Rated DC power
2,507.5 kW · at terminals
DC voltage range
1,040 – 1,497.6 V
DC bus topology
Single bus · 12 HV boxes
BMS response
< 100 ms · trip / disconnect
DC round-trip
≥ 96 % (block only)
Discharge duration
2.0 h at full nameplate

Container Topology

Racks per container
12
Packs per rack
4 (48 packs total)
High-voltage boxes
12 (one per rack)
Cells per container
4,992 prismatic LFP
Per-rack capacity
417.9 kWh / 208.9 kW
Form factor
20-ft ISO container ± 10 mm

Cell and Stack

Chemistry
LFP · LiFePO₄ prismatic
Cell model
IFP72175207-314Ah
Cell architecture
1P104S per pack
BMS architecture
Three-stage (cell · pack · rack)

Thermal and Enclosure

Operating temperature
−40 °C to +50 °C (>45 °C derating)
Cooling method
Closed-loop liquid (battery)
Coolant
Propylene glycol / water · 50/50
Coolant flow
60 L/min per rack
Pack ingress
IP67
Container ingress
IP55
Acoustic
≤ 75 dB(A)
Fire suppression
Aerosol · sprinkler · smoke / heat / Li-ion

Mechanical

External dimensions (L×W×H)
6,056 × 2,438 × 2,896 mm
Mass (full container)
43,500 ± 500 kg
Footprint
14.77 m² · 14.0 t/MWh class
Lifting
ISO corner castings · forklift pockets

Standards, Comms and Cyber

Safety listings
UL 1973 / 9540A
IEC pathway
62619 · 60730 · 61030 · 60529
Transport
VN 38-3 · UN 3480
Comms
RS485 · RS232 · RJ45 · CAN · Ethernet · 4G/LTE
Protocols
Modbus TCP/RTU · CAN · MQTT · DNP3 (opt)
Entropy source (option)
Hardware QRNG · Quantum eMotion
Cyber alignment
IEC 62443 · NATO IC26-aware